Skip to main content

HIPAA Compliance

ASCEND provides comprehensive HIPAA compliance for healthcare organizations managing AI agents that access Protected Health Information (PHI).

HIPAA Coverage

RuleStatusImplementation
Privacy RuleCompliantPHI access controls, audit trails
Security RuleCompliantTechnical safeguards, encryption
Breach NotificationCompliantIncident detection, reporting
Enforcement RuleCompliantPolicy enforcement, penalties

Security Rule Safeguards

Administrative Safeguards (164.308)

164.308(a)(1) - Security Management Process

Requirement: Implement policies and procedures to prevent, detect, contain, and correct security violations.

Ascend Implementation:

ControlImplementationEvidence
Risk AnalysisContinuous risk assessmentRisk reports
Risk ManagementAutomated risk mitigationMitigation logs
Sanction PolicyPolicy violation trackingViolation records
Activity ReviewComprehensive audit trailsAudit logs

Risk Analysis Integration:

{
"action_type": "phi_access",
"risk_assessment": {
"risk_score": 75,
"risk_level": "high",
"hipaa_controls": ["164.308(a)(1)(ii)(A)", "164.312(b)"],
"recommendation": "Verify minimum necessary access",
"requires_approval": true
}
}

164.308(a)(3) - Workforce Security

Requirement: Implement policies and procedures to ensure appropriate access to ePHI.

Ascend Implementation:

ControlImplementationEvidence
AuthorizationRole-based PHI accessRole definitions
ClearanceAccess approval workflowsApproval records
TerminationImmediate access revocationTermination logs

Agent Authorization for PHI:

{
"agent_id": "medical-assistant-agent",
"phi_authorization": {
"enabled": true,
"access_level": "read_only",
"allowed_data_types": ["appointment", "demographics"],
"blocked_data_types": ["diagnosis", "treatment_notes"],
"requires_mfa": true,
"audit_level": "detailed"
}
}

164.308(a)(4) - Information Access Management

Requirement: Implement policies and procedures for authorizing access to ePHI.

Ascend Implementation:

ControlImplementationEvidence
Access AuthorizationExplicit PHI grantsAuthorization logs
Access EstablishmentDocumented access proceduresProcedure records
Access ModificationChange control workflowModification logs

Physical Safeguards (164.310)

164.310(d) - Device and Media Controls

Requirement: Implement policies and procedures for handling electronic media.

Ascend Implementation:

ControlImplementationEvidence
DisposalSecure data deletionDisposal certificates
Media Re-useCryptographic erasureErasure logs
AccountabilityAsset trackingInventory records
Data BackupEncrypted backupsBackup logs

Technical Safeguards (164.312)

164.312(a) - Access Control

Requirement: Implement technical policies and procedures for electronic information systems.

Ascend Implementation:

ControlImplementationEvidence
Unique User IDCognito user IDsIdentity logs
Emergency AccessBreak-glass proceduresEmergency access logs
Automatic LogoffSession timeout (15 min)Session logs
EncryptionAES-256 at restEncryption config

PHI Access Control Example:

# Healthcare action types with HIPAA-specific controls
"phi_access": {
"attack_vector": "NETWORK",
"attack_complexity": "LOW",
"privileges_required": "HIGH",
"scope": "UNCHANGED",
"confidentiality_impact": "HIGH",
"integrity_impact": "NONE",
"availability_impact": "NONE",
"hipaa_control": "164.312(a)(1)"
}

164.312(b) - Audit Controls

Requirement: Implement mechanisms to record and examine activity in systems containing ePHI.

Ascend Implementation:

ControlImplementationEvidence
Audit LoggingAll PHI access loggedAudit records
Log ReviewAutomated log analysisReview reports
Log ProtectionImmutable audit logsIntegrity verification
Log Retention6-year retentionRetention policy

PHI Audit Trail Structure:

{
"audit_id": "phi_aud_20250115_143052",
"timestamp": "2025-01-15T14:30:52Z",
"hipaa_event_type": "phi_access",
"user_id": 15,
"agent_id": "medical-assistant-agent",
"patient_id_hash": "sha256:abc123...",
"data_accessed": ["demographics", "appointment_history"],
"access_purpose": "appointment_scheduling",
"minimum_necessary_verified": true,
"authorization_method": "role_based_mfa",
"session_id": "sess_xyz789",
"ip_address": "10.0.1.50",
"device_id": "dev_abc123"
}

164.312(c) - Integrity Controls

Requirement: Implement policies to protect ePHI from improper alteration or destruction.

Ascend Implementation:

ControlImplementationEvidence
Data ValidationInput/output validationValidation logs
Integrity ChecksCryptographic hashingHash records
Change DetectionModification alertsAlert logs
Version ControlPHI change historyVersion records

164.312(d) - Person or Entity Authentication

Requirement: Implement procedures to verify identity before granting access.

Ascend Implementation:

ControlImplementationEvidence
User AuthenticationCognito MFAAuth logs
Agent AuthenticationAPI key + certificateAuth records
Session ValidationJWT token verificationSession logs
Re-authenticationStep-up auth for PHIRe-auth logs

164.312(e) - Transmission Security

Requirement: Implement technical security measures for ePHI transmission.

Ascend Implementation:

ControlImplementationEvidence
EncryptionTLS 1.3Certificate logs
Integrity ControlsHMAC signaturesIntegrity logs
Network SecurityVPC isolationNetwork config

Healthcare Action Types

Ascend includes specialized healthcare action types with HIPAA-specific risk scoring:

PHI Access Actions

Action TypeRisk LevelHIPAA ControlCVSS Score
phi_accessHigh164.312(a)(1)6.5
phi_modifyCritical164.312(c)(1)8.1
phi_exportCritical164.312(e)(1)8.5
phi_deleteCritical164.312(c)(1)9.1

Clinical Actions

Action TypeRisk LevelHIPAA ControlCVSS Score
prescription_writeCritical164.312(c)(1)8.5
diagnosis_modifyCritical164.312(c)(1)8.5
lab_result_accessHigh164.312(a)(1)6.5
imaging_accessHigh164.312(a)(1)6.5

Administrative Actions

Action TypeRisk LevelHIPAA ControlCVSS Score
patient_registerMedium164.312(a)(1)4.5
appointment_createLow164.312(a)(1)2.5
billing_accessMedium164.312(a)(1)5.0
insurance_verifyMedium164.312(e)(1)4.5

Minimum Necessary Standard

ASCEND enforces the HIPAA minimum necessary standard:

Configuration

{
"agent_id": "medical-assistant-agent",
"minimum_necessary": {
"enabled": true,
"data_scope": "task_specific",
"field_restrictions": {
"patient_name": "allowed",
"date_of_birth": "allowed",
"ssn": "blocked",
"full_medical_history": "blocked"
},
"purpose_validation": true,
"access_justification_required": true
}
}

Enforcement

{
"action_type": "phi_access",
"minimum_necessary_check": {
"passed": true,
"requested_fields": ["patient_name", "appointment_date"],
"allowed_fields": ["patient_name", "appointment_date"],
"blocked_fields": [],
"purpose": "appointment_scheduling",
"purpose_valid": true
}
}

Business Associate Agreement

Ascend operates as a Business Associate under HIPAA:

BAA Coverage

AspectCoverage
PHI ProcessingCovered
PHI StorageCovered
PHI TransmissionCovered
Subcontractor ManagementCovered
Breach Notification24-hour notification
Security ObligationsFull compliance

BAA Request

Contact compliance@owkai.app for BAA execution.


Breach Detection and Notification

Automated Breach Detection

{
"breach_detection": {
"enabled": true,
"detection_types": [
"unauthorized_phi_access",
"bulk_phi_export",
"phi_access_after_hours",
"phi_access_unusual_volume",
"phi_access_unauthorized_location"
],
"alert_threshold": "immediate",
"notification_contacts": ["hipaa-officer@company.com"]
}
}

Breach Response Workflow

┌─────────────────────────────────────────────────────────────────┐
│ BREACH RESPONSE WORKFLOW │
├─────────────────────────────────────────────────────────────────┤
│ │
│ Detection → Assessment → Containment → Notification → Remediation
│ │ │ │ │ │ │
│ │ │ │ │ │ │
│ Automated Risk Score Agent 60-day HHS Root │
│ Alerting Calculation Suspend Deadline Cause │
│ │
└─────────────────────────────────────────────────────────────────┘

Compliance Reporting

HIPAA Audit Report

# Generate HIPAA compliance report
curl -X POST "https://pilot.owkai.app/api/compliance/export/hipaa" \
-H "X-API-Key: your_api_key" \
-H "Content-Type: application/json" \
-d '{
"period_start": "2025-01-01",
"period_end": "2025-01-31",
"report_type": "full_audit",
"include_phi_access_logs": true
}'

Report Contents

SectionDescription
PHI Access SummaryAll PHI access events
User ActivityUser-level access patterns
Agent ActivityAgent-level PHI interactions
Risk EventsHigh-risk PHI access events
Policy ViolationsHIPAA policy violations
Remediation StatusViolation remediation tracking

Healthcare Agent Configuration

{
"agent_id": "healthcare-agent",
"agent_type": "supervised",
"hipaa_configuration": {
"phi_access_enabled": true,
"minimum_necessary_enforced": true,
"access_justification_required": true,
"mfa_required": true,
"session_timeout_minutes": 15,
"audit_level": "detailed",
"allowed_phi_types": ["demographics", "appointments"],
"blocked_phi_types": ["ssn", "full_medical_history", "mental_health"],
"operating_hours": {
"enabled": true,
"start": "06:00",
"end": "22:00",
"timezone": "America/New_York"
},
"rate_limits": {
"phi_access_per_hour": 100,
"phi_export_per_day": 10
}
}
}

HIPAA Training Resources

ASCEND provides HIPAA training materials for AI governance:

ResourceDescriptionAccess
Agent Configuration GuidePHI access setupDocumentation
Audit Log ReviewUnderstanding PHI audit trailsDocumentation
Breach Response PlaybookIncident response proceduresOn request
BAA TemplateBusiness Associate AgreementOn request

For HIPAA compliance questions, contact compliance@owkai.app